Page 1
RegulatoR, Keyless Locking 16
SlamCAM spacer discs (if so equipped) can be inserted between the lock barrel
and SlamCAM mechanism to adjust the backset. See image below:
FlexaCam adaptors (if so equipped) can be attached to the cam to provide up to
12 different dimensional variations. See image below:
Rev. B 1/14
PN: 333153000000
RegulatoR, Keyless Locking 1
Instruction Manual

Page 2
RegulatoR, Keyless Locking 2
Thank you for purchasing the CompX RegulatoR. The RegulatoR is an
innovative solution for locking cabinet doors and drawers. It can mount to
cabinet doors or drawers with a material thickness of 1/32” to 1-7/16”.
Powered by 2-AAA batteries (included), RegulatoR operates using a 4 to 8 digit
code. Operation is simple: type a valid code and press ENTER. Then just turn
the lever to the locked or unlocked position.
RegulatoR is easy to install, and offers:
Programmable user and supervisor codes
Programmable modes of operation
Programmable reset features
RegulatoR is intended for interior use only.
Operating Temperature: 50°F – 120°F (10°C – 48°C)
Note: It is strongly recommended that batteries be replaced on an annual basis.
In the event the batteries should die, they can be replaced via the external battery
compartment.
RegulatoR, Keyless Locking 15

Page 3
RegulatoR, Keyless Locking 14
Reset User Code to Factory Default 1234
(Does not apply to Single Use Mode)
To reset the User Code to the factory default 1234 follow the steps on page 8 to
enter programming mode.
There is a 10 second programming time limit between each step. If RegulatoR
times out or error is made, programming will end and you will need to enter
programming mode again.
1. Place RegulatoR into programming mode (see page 8).
2. Type 8888 and then press the ENTER button.
3. If successful, the green indicator light will illuminate for 1 second.
Continue programming or press 9 and then ENTER to exit programming.
RegulatoR, Keyless Locking 3
Packaged Components
CompX RegulatoR is offered in two versions: Manual Lock and Self Lock.
Contents will vary depending on the version.
Contents – Manual Lock Version:
Manual RegulatoR Lock Assembly
2 AAA alkaline batteries
1 Offset locking cam / 1 Straight locking cam
FlexaCam adapters
Mounting hardware
Contents – Self Lock Version:
Self Locking RegulatoR Lock assembly featuring SlamCAM
2 AAA alkaline batteries
SlamCAM spacer discs
Mounting hardware
Each lock contains 2 green stickers that are needed for resetting RegulatoR. In
the event RegulatoR needs reset, one green sticker is placed on the back of the
device. The remaining green sticker should be saved in a safe and secure
location for future reference.
Care and Cleaning
To clean the RegulatoR surface, apply non-acid based cleaner to a clean cotton
cloth; do not spray cleaner directly on the RegulatoR. Wipe down keypad and its
respective housing surfaces of excess cleaner.

Page 4
RegulatoR, Keyless Locking 4
Powering Up and Battery Installation
CompX RegulatoR is shipped with two AAA batteries. While RegulatoR
features a low battery indicator, annual battery replacement is recommended.
Mixing batteries of different chemistries could damage the RegulatoR resulting
in lock failure.
To power up RegulatoR, remove the red tag. Lock is now ready for use.
A T-15 pin in head Torx® (6-lobe) will be required to remove the battery cover.
(Not Included)
To change batteries:
1. Loosen the retaining
screw.
2. Remove battery cover.
3. Press CLEAR 5 times.
4. Insert new batteries as
shown in the illustration.
5. Reinstall battery cover,
tighten retaining screw.
RegulatoR, Keyless Locking 13
Programming Security Timeout ON / Security Timeout OFF
Warning: Security Timeout ON will disable the RegulatoR from use for 5
minutes when 5 invalid attempts to unlock RegulatoR occur. During this time,
RegulatoR will not unlock with either the valid user or supervisor code.
To change the RegulatoR to Security Timeout ON or OFF, follow the steps on
page 8 to enter programming mode.
There is a 10 second programming time limit between each step. If RegulatoR
times out or error is made, programming will end and you will need to enter
programming mode again.
1. Place RegulatoR into programming mode see page 8).
a. To turn Security Timeout ON, type 11 and then press
ENTER.
OR
b. To turn Security Timeout OFF, type 10 and then press
ENTER.
2. If successful, the green indicator light will illuminate for 1 second.
Continue programming or press 9 and then ENTER to exit programming.

Page 5
RegulatoR, Keyless Locking 12
Programming Single Use Timeout ON / Single Use Timeout OFF
Warning: Manual Lock - Single Use Timeout ON is a feature to prevent users
from occupying a shared use locker or cabinet for a prolonged period of time.
Turning this feature on will disable the user code after a programmable amount
of time. After this time elapses, RegulatoR and can only be opened with the
supervisor code.
To change the RegulatoR to Single Use Timeout ON or OFF, follow the steps
on page 8 to enter programming mode.
There is a 10 second programming time limit between each step. If RegulatoR
times out or an error is made, programming will end and you will need to enter
programming mode again.
1. Place RegulatoR into programming mode (see page 8).
a. To set Timeout ON, type 2XX and then press ENTER.
(XX represents a time period from 04 - 12 in whole hours.)
OR
b. To turn Timeout OFF, type 20 and then press ENTER.
3. If successful, the green indicator light will illuminate for 1 second.
Continue programming or press 9 and then ENTER to exit programming.
RegulatoR, Keyless Locking 5
Programming – Introduction
CompX RegulatoR is easy to program and operate. Type the user code (factory
default 1234) and press ENTER to lock or unlock the cabinet.
The supervisor can change operating codes, modes and restore lock settings.
While RegulatoR is easy to program, we highly recommend reading the
complete programming instructions prior to making any changes. Remember to
keep track of any programming changes.
Button locations, indicator lights and knob referenced in the programming
instructions are shown below.
CLEAR button erases any key input made in error
Indicator Lights
Green – Indicates button
input and valid code
Yellow - Indicates low
battery or program mode.
Red – Indicates incorrect
entry
Knob is always rotated
clockwise to unlock
ENTER button is used to complete code
and counter clockwise to lock
and begin programming

Page 6
RegulatoR, Keyless Locking 6
CompX RegulatoR is offered with Self Lock featuring SlamCAM. If your lock
is the Self Lock version, follow the directions below to unlock and lock the
RegulatoR:
To operate the Self Lock version of RegulatoR:
Type a valid code, press ENTER and rotate knob
clockwise 90°, hold knob until door or drawer is
open. Release knob, RegulatoR knob will return
to the locked position. Door or drawer can be
closed at any time.
RegulatoR, Keyless Locking 11
CompX RegulatoR features several modes of operation. These functions can be
changed using the following instructions with a valid supervisor code.
Programming Single Use Mode / Standard Mode
Single Use Mode allows for a revolving user code so multiple people may use
the lock without having to reprogram the RegulatoR each time.
Note: This mode cannot be used with Self Lock with SlamCAM.
Standard Mode RegulatoR operates with a fixed code. To change the code,
follow the Changing the User Code steps on page 9.
To change the RegulatoR to Single Use or Standard Mode, follow the steps on
page 8 to enter programming mode.
There is a 10 second programming time limit between each step. If RegulatoR
times out or an error is made, programming will end and you will need to enter
programming mode again.
1. Place RegulatoR into programming mode (see page 8).
a. To turn Single Use Mode “ON”: type 51 and then press
ENTER.
OR
b. To return to Standard Mode: type 50 and then press ENTER.
2. If successful, the green indicator light will illuminate for 1 second.
Note: Returning to Standard Mode will reset the factory user default code
(1234).
Continue programming or press 9 and then ENTER to exit programming.

Page 7
RegulatoR, Keyless Locking 10
Changing the Supervisor Code
To change the supervisor code, follow the steps on page 8 to enter programming
mode.
The factory default supervisor code is 12345 (supervisor codes must be 4 to 8
digits in length.)
There is a 10 second programming time limit between each step. If RegulatoR
times out or an error is made, programming will end and you will need to enter
programming mode again.
1. Place RegulatoR into programming mode (see page 8).
2. Press 2 and then press ENTER.
3. Type the current supervisor code and press ENTER.
4. Type the new supervisor code and press ENTER.
5. Retype the new supervisor code and press ENTER.
6. If successful, the green indicator light will illuminate for 1 second.
Continue programming or press 9 and then ENTER to exit programming.
RegulatoR features a reset code which will restore the default supervisor code
and user code. RegulatoR was shipped with reset stickers; one attached to the
back of the RegulatoR and an extra sticker that should be saved in a safe and
secure location for future reference.
To restore the factory default supervisor and user code, type the Reset Code
assigned to the RegulatoR and press ENTER.
RegulatoR, Keyless Locking 7
CompX RegulatoR is offered in a Manual Lock version. If your lock is the
Manual Lock version follow the directions below to unlock and lock the
RegulatoR.
To operate Manual Lock version of
RegulatoR:
To unlock, type a valid code, press
ENTER and rotate knob clockwise 90°.
To lock, rotate knob 90° counter
clockwise.

Page 8
RegulatoR, Keyless Locking 8
RegulatoR Programming Mode
To enter programming mode you must know the supervisor code. The default
supervisor code is 12345. Once in programming mode, multiple changes can be
made prior to exiting programming.
There is a 10 second programming time limit between each step. If RegulatoR
times out or an error is made, programming will end and you will need to enter
programming mode again.
1. Lock must be in the locked position prior to entering programming
mode.
2. Type supervisor code and press ENTER.
3. Turn knob clockwise 90° to the unlocked position and press and hold
ENTER for 3 seconds (yellow indicator light will illuminate).
If product is Self Lock with the SlamCAM feature you can
now let go of the knob.
4. With the yellow indicator light illuminated, programming can begin.
RegulatoR, Keyless Locking 9
Changing the User Code
To change the user code, follow the steps on page 8 to enter programming mode.
The factory default user code is 1234 (User codes must be 4 to 8 digits in
length.)
There is a 10 second programming time limit between each step. If RegulatoR
times out or an error is made, programming will end and you will need to enter
programming mode again.
1. Place RegulatoR into programming mode (see page 8).
2. Press 1 and then press ENTER.
3. Type the current user code and press ENTER.
4. Type the new user code and press ENTER.
5. Retype the new user code and press ENTER.
6. If successful, the green indicator light will illuminate for 1 second.
Continue programming or press 9 and then ENTER to exit programming.