CompX eLock Instructions
Thank you for purchasing the CompX eLock. The information contained in these instructions is intended to serve as a
guide so as to allow the eLock to be quickly and easily put into service. CompX’s Network eLock (if equipped) can be
configured to work in conjunction with existing 802.11g or Ethernet networks, making it the 1st and only product to
provide networked access control and temperature monitoring in one device.
For complete set up and installation instructions for networked and stand-alone eLocks, please see the “Help” section
in CompX’s LockView v4 software.
1. 3-position LCD adjustment
2. Dot matrix LCD
3. Wi-Fi antenna cover (if equipped)
4. Red LED & Green LED
5. Network button (blue LED)
6. Alpha-numeric keypad
7. USB port (USB A to mini B cable)
8. “CLEAR” button
9. Beeper location
10. “UP” button
11. “BACK/CANCEL” button
12. “MENU” button
13. “NEXT/SELECT” button
14. “DOWN” button
15. - button
16. + button
17. “LO BATT” indicator
18. Battery pack (6 AA) (BATTERIES
NOT INCLUDED)
19. AC adapter plug-in (2.5 mm)
(ADAPTER NOT INCLUDED)
20. Ethernet connector (if equipped)
(ETHERNET CABLE NOT INCLUDED)
21. Magstripe reader location (if
equipped)
22. “ENTER” button
23. HID PROX or HID iCLASS reader
location (if equipped)
24. Door switch connector (SWITCH
NOT INCLUDED)
25. Dual eLatch connector (if
equipped) (LATCH NOT INCLUDED)
26. RTD probe for temperature
monitoring (if equipped)

Page 2
2
CompX eLock Instructions continued
Unit Features:
◆ Choose 802.11g or Ethernet Networked configurations that
uses the facilities existing infrastructure for actual 2-way
read/write communication
◆ Each eLock can hold any combination of up to 3,000
Supervisors and Users
◆ Choose a model to use existing HID Prox, HID iCLASS, or 3
track magstripe card credentials that can be programmed to
operate each eLock
◆ View, print and download a 15,000 event access audit trail
via the LockView Software (see LockView Instruction Manual
for complete audit trail details)
◆ View, print and download a 500,000 event temperature
audit via the LockView Software (temp monitoring required)
(see LockView Instruction Manual for complete audit trail
details)
◆ Standard Temperature Monitoring eLock
-40ºC to 100ºC (-40º F to 212º F)
◆ Ultra Low Temperature Monitoring eLock
-100º C to -40º C (-148º F to -40º F)
◆ Accuracy within +/- 0.5º C (temp monitoring required)
◆ NIST certification available (temp monitoring required)
◆ Interactive 128 x 64 dot matrix LCD with blue backlight that
adjusts to 3 different angles for easy viewing
◆ Remote Notification System with programmable escalating
alerts via SMTP email; SMS text, voice and fax (Networked
eLock & LockView Software required)
◆ Spring bolt latching mechanism provides automatic
relocking
◆ Optional second latch drive output (requires additional
hardware)
◆ Door position switch input (requires additional hardware)
◆ Membrane keypads with stainless steel domes provides
durable performance and easy cleaning
◆ Detachable mounting plate simplifies installation
◆ Choose from 3 different mounting configurations (vertical,
horizontal right hinge, horizontal left hinge) that will fit most
refrigerators, freezers, and incubators
What’s in the box?
◆ 1 – eLock
◆ 1 – eLock mounting plate
◆ 1 – strike (8” for standard or 14” for ultra low)
◆ 1 – strike plate cover
◆ 8 – #8 x 3/8” Phillips flat head mounting plate sheet metal
screw
◆ 2 – #8 x 1/2” Phillips pan head strike plate sheet metal
screw
◆ 2 – #8 x 1/2” pin-in Torx flat head strike plate cover machine
screw
◆ 2 – 7 1/2” x 1” strike plate foam tape
◆ 2 – 5 1/2” x 1” mounting plate foam tape
◆ 1 – 4 1/2” x 1” mounting plate foam tape
◆ 4 – adhesive backed temperature cable mounting clip
(temperature monitoring only)
◆ 1 – adhesive backed temperature probe mounting clip
(temperature monitoring only)
◆ 1 – battery cover that includes knock-out for Ethernet (if
equipped) and AC power adapter (not included)
◆ 1 – warranty card
◆ 1 – serial code sticker set
◆ 1 – in-box instructions
What’s needed?
◆ T15 pin-in Torx (6-lobe) bit or driver
◆ 6 AA alkaline batteries
◆ ruler or tape measure
◆ drill (if screws will be uses as the method of attachment)
◆ pencil
Care and Cleaning
The eLock is a battery operated device, therefore, it should
be part of a regular battery maintenance program.
To clean the surface of the eLock, apply non-acid based
cleaner to a clean cotton cloth; do not spray cleaner directly
on the eLock. Wipe down keypad and housing taking care
around the beeper opening and edges of keypads. Wipe
excess cleaner off of all surfaces.

Page 3
3
CompX eLock Instructions continued
Setting up the eLock
Getting Started Out of the Box
If the eLock is stand-alone (direct connection to LockView
Software v4.1) and will be used in conjunction with CompX’s
LockView Software v4.1, please follow the LockView Mode
Instructions below.
For Networked (802.11g or Ethernet) eLocks, please
follow the CompX eLock Database & Network Configuration
& Install Manual and the CompX LockView Software
Instruction Manual before proceeding.
The eLock is shipped in FACTORY mode.
Install 6 AA alkaline batteries. (not included)
1. The first time the eLock is powered up, FACTORY will be
displayed in the upper left hand corner of the LCD.
2. Press “MENU.”
3. Press “DOWN” button to highlight CREDENTIAL MENU and
press “NEXT/SELECT.”
4. Highlight ADD CREDENTIAL and press “NEXT/SELECT.”
5. CREDENTIAL TO ADD will be displayed.
When in FACTORY mode, the default status level for the first
credential is Supervisor, as Supervisor status is required to
allow access to further manual programming features.
There are two status levels; Supervisor and User. Only
Supervisors are, among other things, allowed to ADD,
DELETE, VIEW or EDIT Users and other Supervisors.
6. Scan first supervisor’s card credential (if equipped) or enter
first supervisor’s 4-14 digit PIN and press “ENTER.”
The Supervisor will be added to slot number 1.
7. To change the slot number, press “UP” to highlight and then
+ / - to move to next available slot; or use the numeric
keypad to enter the desired slot number
Press “NEXT/SELECT” when done.
8. CREDENTIAL NAME ENTRY will appear.
Press 2 - 9 for A - Z; press 1 for - , . , + or _ ; press 0 for
“space”; press and hold 0 - 9 for numbers (the maximum
number of allowed characters is 14).
9. Press “ENTER” when done. STORED will be displayed when
complete.
Using the various eLock LCD menu options, manual
programming can continue.
See CompX eLock Manual Programming Guide for complete
options and instructions.
10. Press BACK/CANCEL to exit.
Operating the eLock
Follow the instructions below to operate the eLock.
PIN CREDENTIAL
1. Enter a valid PIN (between 4 - 14 digits) and
2. Press “ENTER.”
CARD CREDENTIAL
If the eLock is equipped with a card reader (HID Prox, HID
iCLASS or a Magstripe)
1. Present a valid card within range of the HID reader or slide
the magstripe card through the magstripe reader.
DUAL CREDENTIAL
If the User or Supervisor requires a dual credential
1. Enter a valid PIN and press “ENTER” (for keypad credentials)
or present a valid card (for HID Prox or HID iCLASS or
Magstripe credentials).
2. Enter the second credential (4-14 digit PIN) and press
“ENTER.”
NOTE: THE SECOND CREDENTIAL MUST ALWAYS BE
A 4 - 14 DIGIT PIN

Page 4
4
CompX eLock Instructions continued
Methods to begin building
a database of eLocks in
CompX’s LockView Software
Note: Supervisor, User and parameter changes that already
exist in the eLock will automatically be carried into
LockView once the eLock has been enrolled.
For Networked (802.11g or Ethernet) eLocks, please
follow the CompX eLock Database & Network Configuration
& Install Manual and the CompX LockView Software
Instruction Manual before proceeding.
LockView Mode Instructions
(For complete details on how to build a database of users
and eLocks, see the CompX LockView Software Instruction
Manual and CompX eLock Manual Programming Guide)
CompX LockView Software v4.1 must be installed and the
eLock must be in SETUP mode before continuing.
Stand-alone eLocks (Direct USB connection to laptop
computer with LockView is required) There are two methods
that can be used to add eLocks to the LockView software.
Automatic Method
1) With the eLock in SETUP mode, connect the eLock via the
USB cable to the computer on which LockView is installed.
2) Login to LockView.
3) After 30 seconds, the below will appear.
NOTE: After 5 minutes of inactivity, the eLock will exit SETUP
mode.
4) Click Yes.
5) The below will appear.
Type in the name of the lock.
**Once a Lock Name has been chosen in LockView, it can
not be changed. Please be sure the name that is chosen is
the one that will be used in the future.
6) Click Save when done.
7) Go to Lock Editor tab in Lock/User Editor.
8) Left click to highlight the name of the lock and then click Edit
Lock.
9) Verify and/or adjust all other lock parameters. (See LockView
Instruction Manual for complete details.)
10) Click OK when done.
Manual Method
1) Login to LockView.
2) Go to Lock/User Editor; Lock Editor tab and click Add
Lock.
3) Enter the required information: Lock Name; Lock Serial
Number and Setup Code (supplied on green sticker set as
Setup Cd).
**Once the Lock Name has been chosen in LockView, it can
not be changed. Please be sure the name that is chosen is
the one that will be used in the future.
4) Verify and/or adjust all other lock parameters and click OK.
(See LockView Instruction Manual for complete details on
these options)
5) With the eLock in SETUP mode, connect the eLock via the
USB cable to the computer on which LockView is installed.
6) After 30 seconds, the lock will be updated in LockView. Click
Refresh to prompt the update.
NOTE: After 5 minutes of inactivity, the eLock will exit SETUP
mode.

Page 5
5
CompX eLock Instructions continued
PASSAGE MODE
(LockView software required) To hold the latch bolt in the
open position indefinitely, there is a setting in LockView
called Passage Mode.
Passage Mode can be assigned to an eLock and/or a
Supervisor/User credential.
In LockView, via the Lock Editor, Passage Mode can be
selected so that every valid User or Supervisor that has
access rights to the eLock can place it in passage mode.
In the LockView, via the User Editor, Passage Mode can
be selected for individual Users and Supervisors settings
can place any eLock to which they have access rights into
Passage Mode. This is regardless of whether or not Passage
Mode has been activated in the eLock.
To place an eLock into Passage Mode:
PIN CREDENTIAL
1. Enter a valid PIN (between 4 - 14 digits) and press “ENTER.”
2. Press “ENTER” again. HOLD OPEN will flash; LOCK IS HELD
OPEN will appear in the upper left hand corner of the LCD.
CARD CREDENTIAL
If the eLock is equipped with a card reader (HID Prox, HID
iCLASS or Magstripe):
1. Present a valid card within range of the HID reader or slide
the magstripe card through the magstripe reader.
2. Press “ENTER.” HOLD OPEN will flash; LOCK IS HELD OPEN
will appear in the upper left hand corner of the LCD.
DUAL CREDENTIAL
If the User or Supervisor requires a dual credential:
1. Enter a valid PIN and press “ENTER” (for keypad credentials)
or present a valid card (for HID Prox or HID iCLASS
credentials).
2. Enter the second credential (4-14 digit PIN) and press
“ENTER”
3. Press “ENTER” again. HOLD OPEN will flash; LOCK IS HELD
OPEN will appear in the upper left hand corner of the LCD.
NOTE: THE SECOND CREDENTIAL MUST ALWAYS BE A 4 - 14
DIGIT PIN
To EXIT Passage Mode (re-lock the unit/extend the eLock
latch bolt):
PIN CREDENTIAL
1. Enter a valid PIN (between 4 - 14 digits)
2. Press “ENTER.” EXITING PASSAGE MODE will flash on the
LCD and the latch bolt will extend.
CARD CREDENTIAL
If the eLock is equipped with a card reader (HID Prox, HID
iCLASS Magstripe):
1. Present a valid card within range of the HID reader or slide
the magstripe card through the magstripe reader. EXITING
PASSAGE MODE will flash on the LCD and the latch bolt will
extend.
DUAL CREDENTIAL
If the User or Supervisor requires a dual credential:
1. Enter the primary valid PIN (for keypad credentials) and
press “ENTER” or present the valid card (for HID Prox, HID
iCLASS or Magstripe credentials). EXITING PASSAGE MODE
will flash on the LCD and the latch bolt will extend.

Page 6
6
CompX eLock Instructions continued
Below are the FACTORY DEFAULT SETTINGS for eLocks
equipped with temperature monitoring.
NOTE:
1) Permission Levels can only be changed using LockView
software.
2) Permission Levels checked in gray scale cannot be changed.
Provided no Permission Level changes have been made
in LockView, Supervisor status is required to adjust the
following settings via manual programming at the eLock:
Reset Min/Max observations
MIN/MAX OBSERVATIONS IS THE THE HIGHEST AND LOWEST
TEMPERATURE THAT HAS BEEN RECORDED SINCE THE LAST
TIME THE eLock WAS RESET. THIS WILL NOT RESET THE UPPER
AND LOWER LIMITS FOR ALARMING.
At the eLock, press the “UP” button to view the highest
observed temperature or the “DOWN” button to view the
lowest observed temperature recording since the last reset
Set upper/lower limits
UPPER/LOWER LIMITS IS THE HIGHEST AND LOWEST
ACCEPTABLE TEMPERATURE. THE TEMPERATURE RANGE CAN
BE ADJUSTED IN 1/10TH DEGREE INCREMENTS.
The temperature range of a:
Standard Temp eLock: -40°C to 100°C (-40°F to 212°F)
Ultra Low Temp eLock: -100°C to -40°C (-148°F to -40°F)
Set alarm volume
OFF, SOFT, MED, LOUD
Enable/disable the alarm
TURN ALARM ON/OFF
Permission to “Enable/disable the alarm” requires that
permission to “Open while alarm is sounding” is also
granted.
Provided no Permission Level changes have been made
in LockView, BOTH Users* and Supervisors may adjust the
following settings via manual programming at the eLock:
Select Display Formats
HOURS: AM/PM or 24 HOUR
DAY/DATE: MON-SUN MM/DD/YY; MON-SUN MMM D ‘YY;
MON-SUN DD-MM-YY; MON-SUN DD-MMM-YY or MON-SUN
YYYY-MM-DD
TEMP: °FAHRENHEIT or °CELSIUS
Open while alarm is sounding
A VALID CREDENTIAL WILL BE ALLOWED TO OPEN AN eLock
WHILE AN ALARM IS SOUNDING.
*In order for User status credentials to be permitted to
open an eLock while an alarm is sounding, permission for
Supervisors to do so must also be granted.
Mute the alarm
THE ALARM MUST BE TRIGGERED AND THE RECORDED
TEMPERATURE MUST BE OUTSIDE OF THE ACCEPTABLE
PROGRAMMED RANGE IN ORDER SEE THIS FEATURE
Mute can be used to silence a triggered alarm for 10 minutes.
(see Manual Programming Guide for details)
NOTE:
Alarm Delay and Alarm Time can only be adjusted via
LockView.

Page 7
7
Manual Programming Guide
Temperature Menu (if equipped)
CompX eLocks equipped with temperature monitoring have a
number of features that can be adjusted in the TEMPERATURE
MENU using manual programming.
TURN ON/OFF ALARM
1 Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Using the “UP”/“DOWN” button, highlight TEMPERATURE
MENU and press “NEXT/SELECT.”
4. A) TURN ON ALARM will appear if alarm is disabled. Press
“NEXT/SELECT” to enable the alarm. Alarm Now
ENABLED will appear.
B) TURN OFF ALARM will appear if alarm already is enabled.
Press “NEXT/SELECT” to disable the alarm. Alarm Now
DISABLED will appear.
RESET OBSERVED TEMPERATURES
(OBSERVED TEMPERATURES IS THE HIGHEST AND LOWEST TEMPERATURE
THAT HAS BEEN RECORDED SINCE THE LAST TIME THE eLock WAS RESET.
THIS WILL NOT RESET THE UPPER AND LOWER LIMITS FOR ALARMING.
IF THE ALARM TEMPERATURE LIMITS NEED TO BE CHANGED, SEE
TEMPERATURE LIMITS)
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight TEMPERATURE MENU and
press “NEXT/SELECT.”
4. Using the “UP”/“DOWN” button, highlight RESET OBS. TEMPS
and press “NEXT/SELECT.”
5. Reset high and low temperature observations? will appear.
Press ‘UP” and “NEXT/SELECT” to reset.
6. Observations RESET will be displayed.
TEMPERATURE LIMITS
(THE TEMPERATURE RANGE CAN BE ADJUSTED IN 1/10TH DEGREE
INCREMENTS)
Temperature ranges:
Standard Temp eLock: -40°C to 100°C (-40°F to 212°F)
Ultra Low Temp eLock: -100°C to -40°C (-148°F to -40°F)
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight TEMPERATURE MENU and
press “NEXT/SELECT.”
4. Using the “UP”/“DOWN” button, highlight TEMP LIMITS and
press “NEXT/SELECT.”
5. ALARM SETTINGS will appear along with the current MINIMUM
TEMP & MAXIMUM TEMP settings.
6. Press “UP”/“DOWN” buttons to select value and +/- buttons
or numeric keypad to adjust.
7. Press “NEXT/SELECT” when done.
ALARM SETTINGS
(USING ALARM SETTINGS, ALARM VOLUME, ALARM DELAY, ALARM
DURATION AND THE CHIRP WARNING CAN BE ADJUSTED)
Note: Supervisor level status is required to Enable/Disable
the alarm using ALARM SETTINGS.
CHIRP serves two purposes. First, it is an early warning that
the temperature being recorded has gone outside of the
programmed acceptable range. Second, if the temperature
alarm is disabled, the CHIRP feature allows the eLock to
sound an alert.
When CHIRP is “ON” it will sound at the programmed volume
(OFF, SOFT, MED, LOUD) and escalate at the programmed speed
(OFF, SLOW, MED, FAST) until the programmed ALARM DELAY time
has expired and the eLock starts to alarm, or the temperature
goes back in the programmed acceptable range.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight TEMPERATURE MENU and
press “NEXT/SELECT.”
4. Using the “UP”/“DOWN” button, highlight ALARM SETTINGS
and press “NEXT/SELECT.”
5. Alarm Settings will appear along with CHIRP ON/OFF; CHIRP
VOLUME; CHIRP ESCALATION
6. Press “UP”/“DOWN” buttons to select and +/- buttons or
numeric keypad to adjust:
ALARM VOLUME (OFF, SOFT, MED, LOUD)
ALARM DELAY (MINUTES)
ALARM DURATION (MINUTES)
CHIRP (ON/OFF)
CHIRP VOLUME (OFF, SOFT, MED AND LOUD)
CHIRP ESCALATION (OFF SLOW, MED, FAST)
7. Press “NEXT/SELECT” when done.

Page 8
8
Manual Programming Guide
continued
LOG INTERVALS
(THE eLock RECORDS IN MEMORY TEMPERATURE DATA THAT CAN BE
RETRIEVED USING LOCKVIEW. USING LOG INTERVALS, THE FREQUENCY
OF TEMPERATURE RECORDS FOR “IN RANGE” AND “OUT OF RANGE”
MEASUREMENTS CAN BE ADJUSTED)
Only Supervisors are allowed to adjust LOG INTERVALS.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight TEMPERATURE MENU and
press “NEXT/SELECT.”
4. Using the “UP / “DOWN” button, highlight LOG INTERVALS
and press “NEXT/SELECT.”
5. Log Intervals will appear along with WHEN IN-RANGE and WHEN
OUT-OF-RANGE
6. Press “UP”/“DOWN” buttons to select value and +/- buttons
or numeric keypad to adjust.
7. Press “NEXT/SELECT” when done.
MUTE ALARM
(THE ALARM MUST BE TRIGGERED AND THE RECORDED TEMPERATURE
MUST BE OUTSIDE OF THE ACCEPTABLE PROGRAMMED RANGE IN ORDER
TO MAKE USE OF THIS FEATURE)
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight TEMPERATURE MENU and
press “NEXT/SELECT.”
4. Using the “UP / “DOWN” button, highlight MUTE ALARM and
press “NEXT/SELECT.”
5. MUTED TEMPORARILY will flash. Note: THERMAL ALARM
MUTED will be displayed on the main screen.
A) After muting a triggered alarm, if the temperature returns
to the acceptable programmed range within 10 minutes,
THERMAL ALARM MUTED will no longer be displayed.
B) After muting a triggered alarm, if the temperature fails
to return to the acceptable programmed range after 10
minutes, **THERMAL WARNING** will appear and the
programmed Alarm Delay time will start. If this Alarm
Delay time expires and the temperature remains outside
of the acceptable programmed range, the alarm will be
triggered and **THERMAL ALARM** will appear on the
main screen.
Note: Choosing to MUTE an alarm that has already been MUTED will
extend the remaining mute time by another 10 minutes.
RESET ALARM
(THE ALARM MUST BE TRIGGERED AND THE RECORDED TEMPERATURE
MUST HAVE RETURNED TO THE ACCEPTABLE PROGRAMMED RANGE IN
ORDER TO MAKE USE OF THIS FEATURE)
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight TEMPERATURE MENU and
press “NEXT/SELECT.”
4. Using the “UP / “DOWN” button, highlight RESET ALARM and
press “NEXT/SELECT.”
5. ALARM RESET will flash. Note: **THERMAL ALARM** will
no longer be displayed on the main screen.
A) **THERMAL ALARM** will continue to be displayed
indefinitely until the alarm is reset by following the above
RESET ALARM steps.
B) If the temperature does not return to the acceptable
programmed range after 10 minutes, **THERMAL
WARNING** will appear on the main screen.
If the temperature does not return to the acceptable range
within the programmed alarm delay time, the alarm will be
triggered and **THERMAL ALARM** will appear on the main
screen.
Credential Menu
ADD CREDENTIAL
Note: There are two status levels; Supervisor and User. Each
eLock can hold any combination of up to 3,000 Supervisors
and Users.
Only Supervisors are allowed to ADD Users and Supervisors.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and Press
“ENTER.”
3. Press “DOWN” button to highlight CREDENTIAL MENU and
press “NEXT/SELECT.”
4. Highlight ADD CREDENTIAL and press “NEXT/SELECT.”
5. CREDENTIAL TO ADD will be displayed. Scan new credential
or enter new 4-14 digit PIN and Press “ENTER.”
6. Adding credential will be displayed.
7. Default status is User. To change status to Supervisor press
the + button.
8. The new User/Supervisor will be added to the next available
slot number. To change the slot number, press “UP” and then
+/- to move to next available slot; or use the numeric keypad
to enter the desired slot number and press “NEXT/SELECT.”

Page 9
9
Manual Programming Guide
continued
9. CREDENTIAL NAME ENTRY will appear. Press 2 - 9 for A - Z;
press 1 for -, ., + or _; press 0 for “space”; press and hold
0 - 9 for numbers. (Maximum number of allowed characters
is 14.)
10. Press “ENTER” when done. STORED will be displayed when
complete.
DELETE CREDENTIAL
Note: There are two status levels; Supervisor and User.
Only Supervisors are allowed to DELETE Users and
Supervisors.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and Press
“ENTER”
3. Press “DOWN” button to highlight CREDENTIAL MENU and
press “NEXT/SELECT”
4. Highlight DELETE CREDENTIAL and press “NEXT/SELECT”
5. Credential to Delete will be displayed. All of the occupied
slots along with the name (if one exists) will be listed. If
the status of the credential is a supervisor, an asterisk (*)
appears next to the slot number. Press “MENU” to re-sort
by slot number, alphabetically by name, or showing all
supervisors first.
6. Press ‘UP” / “DOWN” to scroll by line or +/- to scroll by
page to highlight credential to be deleted and press “NEXT/
SELECT.”
7. Press “UP” and “NEXT/SELECT” to delete. DELETED will be
displayed when complete.
8. Press “BACK/CANCEL” to return to CREDENTIAL MENU.
VIEW CREDENTIAL
Note: There are two status levels; Supervisor and User.
Only Supervisors are allowed to VIEW Users and Supervisors.
1. Press “MENU” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and Press
“ENTER.”
3. Press “DOWN” button to highlight CREDENTIAL MENU and
press “NEXT/SELECT”
4. Highlight VIEW CREDENTIAL and press “NEXT/SELECT”
5. Credential to View will be displayed. All of the occupied slots
along with the name (if one exists) will be listed. If the status
of the credential is a supervisor, an asterisk (*) appears next
to the slot number. Press “MENU” to re-sort by slot number,
alphabetically by name, or showing all supervisors first.
6. Press “UP”/“DOWN” to scroll by line or +/- to scroll by page to
highlight credential to be viewed and press “NEXT/SELECT.”
7. Press “NEXT/SELECT” to display NAME, SLOT NUMBER, LAST
ACCESS ATTEMPT.
8. Press “DOWN” to display CREDENTIAL TYPE (KEYPAD, PROXCARD
or MAGSTRIPE CARD)
9. Press “DOWN” again to display the ACCESS SCHEDULE
(TIME AND DAY RESTRICTIONS AS SET IN LOCKVIEW).
10. Press “BACK/CANCEL” to return to CREDENTIAL MENU.
EDIT CREDENTIAL
Note: There are two status levels; Supervisor and User.
Only Supervisors are allowed to EDIT Users and Supervisors.
1. Press “MENU” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and Press
“ENTER”
3. Press “DOWN” button to highlight CREDENTIAL MENU and
press “NEXT/SELECT”
4. Highlight EDIT CREDENTIAL and press “NEXT/SELECT”
5. Credential to Edit will be displayed. All of the occupied slots
along with the name (if one exists) will be listed. If the status
of the credential is a supervisor, an asterisk (*) appears next
to the slot number. Press “MENU” to re-sort by slot number,
alphabetically by name, or showing all supervisors first.
6. Press ‘UP” / “DOWN” to scroll by line or +/- to scroll by page
to highlight credential to be edited.
7. Press “NEXT/SELECT” to edit highlighted credential
8. Press +/- to change Level (Supervisor/User); press “UP/
DOWN” to highlight 2nd PIN. To add a new or change an
existing 2nd PIN, enter a 4 - 14 digit number using the
numeric keypad. Press “ENTER” when done. Confirm the
new/changed PIN by entering it again when prompted. Press
“ENTER” when done.
9. Press “BACK/CANCEL” to return to CREDENTIAL MENU.
SET/EDIT YOUR 2nd PIN
Note: There are two status levels; Supervisor and User.
Only Supervisors are allowed to SET/EDIT YOUR 2nd PIN.
The steps below will make the logged in credential a Dual
Credential Supervisor requiring a 2nd PIN.
Follow the EDIT CREDENTIAL steps to add/change dual
credential status for other Supervisors or Users.
1. Press “MENU” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and Press
“ENTER”
3. Press “DOWN” button to highlight CREDENTIAL MENU and
press “NEXT/SELECT”

Page 10
10
Manual Programming Guide
continued
4. Highlight SET YOUR 2nd PIN and press “NEXT/SELECT.” (EDIT
YOUR 2nd PIN will appear if a second PIN credential already
exists)
5. Type new 2nd PIN will be displayed. Enter new 4 - 14 digit
PIN and press “NEXT/SELECT.”
6. Type 2nd PIN again will appear. Enter the 4 - 14 digit PIN
again and press “NEXT/SELECT.” NEW PIN SET will appear.
Display Formats
Using DISPLAY FORMATS, the following can be adjusted:
HOURS: AM/PM or 24 HOUR
M-F/DATE:
◆ MON-SUN; MM/DD/YY;
◆ MON-SUN; MMM D ‘YY;
◆ MON-SUN; DD-MM-YY;
◆ MON-SUN; DD-MMM-YY
◆ MON-SUN; YYYY-MM-DD
TEMP: °FAHRENHEIT or °CELSIUS
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight DISPLAY FORMATS and
press “NEXT/SELECT.”
4. DISPLAY FORMATTING will be displayed.
5. Press “UP”/“DOWN” buttons to select and +/- buttons to
adjust.
6. Press “NEXT/SELECT” when done.
Set Date/Time
Using SET DATE/TIME, the following can be adjusted:
SETUP TIME ZONE (INCLUDING AUTO DAYLIGHT SAVING)
SET DATE (MONTH, DAY, YEAR)
SET TIME (HOUR, MINUTE, AM/PM)
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight SET DATE/TIME and press
“NEXT/SELECT.”
4. DATE/TIME MENU will be displayed.
5. Press “UP”/“DOWN” to scroll and “NEXT/SELECT” to modify.
6. Press “UP”/“DOWN” buttons to select and +/- buttons to
adjust.
7. Press “NEXT/SELECT” when done.
8. Press “BACK/CANCEL” to return to main menu.
Network Test (if equipped)
Using NETWORK TEST the strength and quality of the eLock
connection to the network is displayed. The IP and MAC
addresses are also shown here.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight NETWORK TEST and press
“NEXT/SELECT.”
4. NET STATUS will be displayed as well as Str: & Qual:, IP
address and MAC address.
5. Press “CLEAR” to exit.
LCD Contrast
Using LCD CONTRAST, the LCD contrast can be adjusted:
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight LCD CONTRAST and press
“NEXT/SELECT.”
4. LCD Contrast will be displayed.
5. Enter 1 - 9 on numeric keypad or +/- buttons to adjust.
6. Press “NEXT/SELECT” when done.
7. Press “BACK/CANCEL” to return to main menu.
LCD Backlight
Using LCD BACKLIGHT the brightness of the display can be
adjusted.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight LCD BACKLIGHT and press
“NEXT/SELECT.”
4. LCD Backlight will be displayed.
5. Enter 0 - 9 on numeric keypad or +/- buttons to adjust.
(“0” = OFF)
6. Press “NEXT/SELECT” when done.

Page 11
11
Manual Programming Guide
continued
Set Beep Volume
Using SET BEEP VOLUME, the audible beep can be
adjusted.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight SET BEEP VOLUME and
press “NEXT/SELECT.”
4. Beep Volume will be displayed.
5. Enter 0 - 9 on numeric keypad or +/- buttons to adjust.
(“0” = MUTE)
6. Press “NEXT/SELECT” when done.
7. Press “BACK/CANCEL” to return to main menu.
Reset Net Schedule
A PROPERLY CONFIGURED AND ENABLED NETWORK eLock
IS REQUIRED TO MAKE USE OF THIS FEATURE.
Only Supervisors are allowed to RESET NET SCHED.
Using RESET NET SCHED. the scheduled network check-in
time can be set.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and Press
“ENTER.”
3. Press “DOWN” button to highlight RESET NET SCHED. and
press “NEXT/SELECT.”
4. NETWORK TIMING RESET will be displayed. The eLock will
follow the programmed or default check-in frequency from
this time of day forward.
For example:
Programmed Update Interval as set in LockView is 12 hours
(twice/day). The time of day was 10 a.m. when the eLock
was initialized.
Therefore, the eLock update time is 10 a.m. and 10 p.m. The
desired update time is 6 a.m. and 6 p.m.
Using the RESET NET SCHED. feature, the above steps should
be followed at 6 a.m. or 6 p.m.

Page 12
12
Installing the VERTICAL mount refrigerator kit
Mount the strike
at least 4" from
NON-hINGED EDGE
of the refrigerator.
There are two main parts of this installation: installing the strike and installing
the eLock assembly. The strike and the eLock assembly can be mounted either
with foam tape or by drilling holes and using screws. It is important to note that
mounting the strike and the eLock assembly are independent of each other. One
can be foam tape mounted, and one can be drill mounted if desired. The two do
not need to be mounted using the same method.
• verify eLock operation before beginning instaLLation •
a. Screw one tamper resistant sheet metal
screw into the center of the strike's slotted
area. Note: The end of the metal strike
needs to curve up.
b. Place the plastic strike cover over the
metal strike. If strike was mounted using
foam tape, please proceed to Step 3.
c. Attach with one tamper resistant machine
screw.
Install the strike
Step
1:
Secure the strike and attach the strike cover (if strike was mounted using foam tape, ONLY do b.)
Step
2:
Foam Tape Installation: Option A
Please note that if foam tape installation
of the strike is used, the strike will not
be adjustable once it's put in place.
a. Clean the top refrigerator as well as the
strike with rubbing alcohol. Wait for the
alcohol to dry.
b. With a pencil, mark refrigerator 6-7/8"
from the front of the door and at least 4"
from the non-hinged edge.
Measure from this line to the front of the
cabinet (dim. “A”); cut a piece of tape
this length.
c. Remove tape backer and affix to end
of strike. The upward curve should be
on top. Apply tape to the opposite side.
Remove backer. Line up strike with line on
refrigerator; apply pressure to seal it on.
Note: The end of the metal
strike needs to curve up.
Option B
Option A
Drilling Installation: Option B
a. Before drilling, verify that there are no
refrigerant lines inside the top of the
refrigerator.
b. Drill a 9/64” hole, 5-7/8” from the
edge of the front of the refrigerator and
at least 4” from the non-hinged edge of
the refrigerator.

Page 13
13
Installing the VERTICAL mount refrigerator kit cont.
The CompX eLock can be mounted to the front of the refrigerator by
using the provided foam tape or by drilling holes and using screws
(provided).
Foam Tape Installation
Please note that if foam tape installation is used, the eLock will
not be adjustable once it is put in place.
a. Clean the front of the refrigerator with rubbing alcohol. Wait for
the alcohol to dry.
b. Click the eLock onto strike plate, ensuring proper latch bolt
engagement and mark the eLock location on the refrigerator
door with a pencil.
c. Remove one side of the protective liner from the
double-sided tape and install on the CompX
refrigerator eLock mounting plate.
d. Attach the mounting plate to the back of the
eLock.
e. Remove remaining protective liner from double-
sided tape.
f. Carefully press eLock onto the refrigerator door in the location as
previously marked.
g. Verify proper operation and alignment.
h. Firmly press eLock onto fridge. Note: Temporary support of
the eLock may be required to allow adequate adhesion time
of the foam tape.
Drilling Installation
a. Cut a 3” piece of double-
sided foam tape and attach
it to the mounting plate
to serve as an location
alignment holder.
b. Attach the mounting plate to
the back of the eLock.
c. Click the eLock onto strike
plate, ensuring proper latch
bolt engagement. Press
eLock onto the refrigerator
door.
d. Remove eLock from mounting plate by
pressing down on the mounting plate release
tab.
e. Drill eight 9/64” holes through the mounting
plate holes into the refrigerator door. Secure
with mounting plate screws. Note: Top two
screws may be omitted if they interfere with
the door handle access.
f. Attach eLock to mounting plate.
g. Verify proper operation and alignment.
Note: If foam tape was used to mount the strike, the eLock
refrigerator kit installation is COMPLETE.
Mount the main CompX eLock® body to the refrigerator door
Step
3:
a. Remove the plastic cover from the strike plate. Drill 9/64"
hole in second opening of strike.
b. If adjustment of strike is needed, loosen the first strike
screw and adjust the strike. Tighten the screw.
c. Drill hole for second screw and install second screw.
d. Attach the plastic strike cover with two tamper resistant
machine screws.
Route cable behind door gasket to hinge point. Probe
should be as close to the product as possible.
Finish installation of the strike (ONLY if drilled installation of strike was used)
Step
4:
Temperature monitoring eLock only
Step
5:

Page 14
14
Installing the HORIZONTAL mount refrigerator kit
Mount the
strike at least
4" from the
top of the
NON-hINGED
EDGE of the
refrigerator.
There are two main parts of this installation: installing the strike and installing the
eLock assembly. The strike and the eLock assembly can be mounted either with foam
tape or by drilling holes and using screws. It is important to note that mounting the
strike and the eLock assembly are independent of each other. One can be foam
tape mounted, and one can be drill mounted if desired. The two do not need to be
mounted using the same method.
a. Screw one tamper resistant sheet metal
screw into the center of the strike's slotted
area. Note: The end of the metal strike
needs to curve out.
b. Place the plastic strike cover over the
metal strike.
c. Attach with one tamper resistant machine
screw.
Install the strike
Step
1:
Foam Tape Installation: Option A
Please note that if foam tape installation
of the strike is used, the strike will not be
adjustable once it's put in place.
a. Clean the side of the refrigerator as well
as the strike with rubbing alcohol. Wait
for the alcohol to dry.
b. Along the non-hinged side of the
refrigerator, make a mark 6-7/8” from
the front edge of door and a minimum of
4” from the top. Measure from this line to
the front of the cabinet (dim. “A”); cut a
piece of tape this length.
c. Remove tape backer and apply tape.
Line up end of strike with the 6-7/8”
mark on side of refrigerator. Ensure strike
is level, and apply using firm pressure.
Install plastic strike cover on metal strike.
Proceed to step 3.
Note: The end of the metal
strike needs to curve out.
Option B
Option A
Secure the strike and attach the strike cover
Step
2:
Drilling Installation: Option B
a. Before drilling, verify that there are no
refrigerant lines inside the side of the
refrigerator.
b. Drill a 9/64” hole, 5-7/8” back from
the edge of the front of the refrigerator
door and at least 4” from the top of the
non-hinged edge of the refrigerator.
• verify eLock operation before beginning instaLLation •

Page 15
15
Installing the HORIZONTAL mount refrigerator kit cont.
Route cable behind door gasket to hinge point. Probe
should be as close to the product as possible.
a. Remove the plastic cover from the strike plate. Drill 9/64”
hole in second opening of strike.
b. If adjustment of strike is needed, loosen up the first strike
screw and adjust the strike. Tighten up the screw.
c. Drill hole for second screw and install.
d. Reattach the plastic strike cover and secure with two
tamper resistant machine screws.
Temperature monitoring eLock only
Step
5:
Mount the CompX eLock® housing to the refrigerator door
Step
3:
Finish installation of the strike (ONLY if drilled installation of strike was used)
Step
4:
The CompX eLock can be mounted to the front of the refrigerator by
using the provided foam tape or by drilling holes and using screws
(provided).
Foam Tape Installation
Please note that if foam tape installation is used, the eLock will
not be adjustable once it is put in place.
a. Clean the front of the refrigerator with rubbing alcohol. Wait for the
alcohol to dry.
b. Click the eLock onto strike plate, ensuring proper latch bolt
engagement and mark the eLock location on the refrigerator door
with a pencil.
c. Remove one side of the protective liner from the
double-sided tape and install on the CompX
refrigerator eLock mounting plate.
d. Attach the mounting plate to the back of the
eLock.
e. Remove remaining protective liner from double-
sided tape.
f. Carefully press eLock onto the refrigerator door in the location as
previously marked.
g. Verify proper operation and alignment.
h. Firmly press eLock onto fridge. Note: Temporary support of the
eLock may be required to allow adequate adhesion time of the
foam tape.
Drilling Installation
a. Cut a 3” piece of double-sided foam tape and attach it to the
mounting plate to serve as an location alignment holder.
b. Attach the mounting plate
to the back of the eLock.
c. Click the eLock onto strike
plate, ensuring proper
latch bolt engagement.
Press eLock onto the
refrigerator door.
d. Remove eLock from
mounting plate by
pressing down on the
mounting plate release
tab.
e. Drill eight 9/64” holes through the mounting
plate holes into the refrigerator door. Secure
with mounting plate screws. Note: Top two
screws may be omitted if they interfere with the
door handle access.
f. Attach eLock to mounting plate.
g. Verify proper operation and alignment.
Note: If foam tape was used to mount the strike, the eLock
refrigerator kit installation is COMPLETE.

Page 16
16
CompX eLock® Accessories
Part #: 332331000000 Rev A.
Copyright 2010 © CompX Security Products / 847.752.2500 / compxwaterloo.net / 715 Center St., Grayslake, IL 60030
Any companies and/or products referred to herein are marks or registered trademarks of their respective companies, owners and/or mark holders.
Temperature
Buffering Glycol Kit
(includes bottle, 8-oz. non-toxic glycol, extra
screw top lid w/probe gasket)
Part Number:
EL-gLycoL-kit
Magstripe User,
Supervisor Card
Part Number:
EL-2004-MSc (no logo)
HID is a trademark of HID Corporation.
Note: product images are not to scale.
LockView® software
❑ Add, edit, view and delete users / supervisors
and their credentials
❑ Add, edit and delete CompX eLocks®
❑ Assign access rights between users / supervisors
and CompX eLocks® in the database
❑ USB or network connection*
❑ Download, view, save, print, archive and delete
audit trails
❑ Dual credential access available
❑ Set real time clock
❑ Time based access restrictions
❑ Create user groups
❑ WindowsTM based
❑ View Temperature Logs
❑ View Temperature Graphs
❑ Edit Temperature Settings
LockView is a Registered Trademark of CompX International. Windows is a trademark of the Microsoft Corporation. Specifications may vary based on user application.
HID® Prox User,
Supervisor Card
Part Number:
EL-2004-Pc (no logo)
EL-icLASS-c
(HID iCLASS user, supervisor card)
LockView®
Software Kit
(1 LockView® CD, 1 USB cable)
Part Number:
EL-LockViEw-4
HID® Prox Tag
Part Number:
EL-2004-Pt
EL-icLASS-t
(HID iCLASS tag)
Screwdriver
Part Number:
EL-DRV-15
Bit
Part Number:
EL-Bit-15
Extra Long
Refrigerator Strike
(included with all ultra low temp. eLocks)
Part Number:
EL-xLStRk-fRkit
* network connection
requires network eLock